The scope of supply of this specification covers the design, fabrication, testing, inspection, supply, validation, and documentation of the FL-300 fluid-bed dryer.
The FL-300 fluid-bed dryer offers efficient mixing and drying capabilities in a single equipment. The transfer of mass and heat is quick, ensuring fast and effective drying. Operating at negative pressure eliminates flying dust, while the equipment's design eliminates dead corners, allowing for easy and thorough cleaning without cross pollution. Heating options include steam or electric heater. The equipment is equipped with antistatic filtering material and features pneumatic operation for safe and convenient use. It meets the requirements of GMP. The inclusion of a stirrer in the bed prevents agglomeration of damp material and ensures uniform drying.
Machine type | 3 | 5 | 15 | 30 | 60 | 120 | 200 | 300 | |
Container | Content (L) | 12 | 22 | 45 | 100 | 220 | 420 | 670 | 1000 |
Diameter (mm) | 300 | 400 | 550 | 700 | 1000 | 1200 | 1400 | 1600 | |
Capability | Minimum (kg) | 1.5 | 4 | 10 | 15 | 30 | 80 | 100 | 150 |
Maximum (kg) | 4.5 | 6 | 20 | 45 | 90 | 160 | 300 | 450 | |
Fan | Capacity (m 3 ) | 480 | 480 | 900 | 1500 | 3000 | 4500 | 6000 | 9000 |
Pressure (mmH 2 o) | 375 | 375 | 480 | 480 | 950 | 950 | 950 | 950 | |
Power (kw) | 2.2 | 2.2 | 4 | 5.5 | 11 | 18.5 | 22 | 30 | |
Steam expenditure Kg/h | 15 | 23 | 42 | 70 | 141 | 211 | 282 | 366 | |
Compressed air expenditure m 3 /min | 0.2 | 0.2 | 0.3 | 0.6 | 0.6 | 0.6 | 0.9 | 0.9 | |
Weight of the main body Kg | 250 | 300 | 700 | 900 | 1100 | 1300 | 1500 | 1800 | |
Steam pressure Mpa | 0.3-0.6 | ||||||||
Temperature | Adjustable from room temperature to 120 | ||||||||
Working time Min | 20-60(Depending on the material processed) | ||||||||
Field % | > 99% | ||||||||
Noise dB(A) | < 70(Fan isolated from the main body) | ||||||||
Components: 1. The main body includes: capturing house, injection house, container atomizer house, solution carrier. 2. The auxiliary machine include: fan, sound deadener, control system. 3. Dedustror recoverer (As customers required). |