BHY-100 Pharmaceutical Machine Tester Density Tester for Powder
Product Description
BHY-100A Tap Density Tester with 1 glass tube/2 glass tube/ 3 glass tube as optional
Meter Volumeter is a product used to measure the tap density of powder, as well as granulated or flaked materials by standardized and repeatable procedures. Standardized tap density analysis is done by BHY-100 according to international standards in.
Applicaitons in metal powders in powder metallurgy (P/M)
-ISO 3953:1993 Metallic Powders-Determination of Tap Density
- ASTM B 527 Standard Test Method for Determination of Tap Density of Metallic Powders and Compounds
Applications in pigments and extenders
-ISO 787/11 General methods of test for pigments and extenders - Part 11 Determination of tamped volume and apparent density after tamping
In addition, HY-100 Tap Density Tester meets international standards such as
- ASTM D 4164 Standard Test Method for Mechanically Tapped Packing Density of Formed Catalyst and Catalyst Carriers
- ASTM D 4781 Standard Test Method for Mechanically Tapped Packing Density of Fine Catalyst Particles and Catalyst Carrier Particles
- IDF 134 Dried milk and dried milk products -- Determination of bulk density
- ISO 8460 Instant coffee -- Determination of free-flow and compacted bulk densities
- ISO 8967 Dried milk and dried milk products -- Determination of bulk density
- ISO 9161 Uranium dioxide powder -- Determination of apparent density and tap density
- JIS K 5101-12-2 Test methods for pigments -- Part 12: Apparent density or apparent specific volume -- Section 2: Mechanically tamped packing method
- JIS Z 25 12
- MPIF 46
Product Parameters
Tap Density Apparatus: settling/tapping apparatus,graduated cylinders
Test Report Output:Integrated Micro Printer(paper width 57mm)
Operation: LED and membrane panel
Number of strokes: selectable from 1-99999
Speed(Variable): USP Method I 300 ± 1 tap/min; USP Method II and ASTM 250 ± 1 tap/min
Drop Height(Variable) : USP Method I 14 ± 2 mm; USP Method II and ASTM 3 ± 0.3 mm
Station Number: Single/Dual/Tri
Accuracy:< 1 tap of 10000 taps
Graduated Cylinder: Glass(calibrated)
Input power: AC 220V 50Hz/110V 60Hz (optional)
Dimensions: 35.8 cm W x 51.6 cm H* x 29.7 cm D (* height with 100mL cylinder)
Weight: 13.8 kg net; 20 kg gross
Recommended size of accoustic cabinet: 60 cm W x 80 cm H x 40 cm D (Internal size)
Principle:
Definition of tapped density is an increased bulk density attained after mechanically tapping a container containing the powder sample. Tapped density is obtained by mechanically tapping a graduated measuring cylinder or vessel containing a powder sample. After observing the initial powder volume or weight, the apparatus measuring cylinder or vessel is mechanically tapped, and volume or weight readings are taken until little further volume or weight change is observed. The mechanical tapping is achieved by raising the cylinder or vessel and allowing it to drop under its own weight a specified distance by either of three methods as during tapping may be preferred to minimize any possible separation of the mass during tapping down. This parameter is very important in packing the material. During tapping of the sample, the smaller particles try to fit themselves in gaps of the larger particles and hence the total volume of the powder reduces.
Features